HV350 General Purpose VFD Vector Frequency Inverter Variable Frequency Converter For Asynchronous Motor Drive Control
| Technical Data | |||
| Projects | Specification Description and Technical Data | ||
| Power input/ | Input voltage | Input voltage: 380V (-15%) to 480V (+10%) Phase: Three-phase | |
| Input power frequency | 50Hz/60Hz ±5% | ||
| Input voltage imbalance | ≤3% | ||
| Output voltage | OV-Input voltage | ||
| Output frequency | 0~600Hz | ||
| Motor type | Asynchronous motor | ||
| Master control performance | Control mode | V/F, OLVC(Open-loop Vector Control), CLVC(Closed-loop Vector Control) | |
| Speed range | 1:10 V/F; 1:100 OLVC; 1:1000 CLVC | ||
| Starting torque | OLVC: 150%(0.5Hz), CLVC: 200%(OHz) | ||
| Torque precision | ≤±5%, in Vector control mode | ||
| Torque ripple | ≤±5%, in Vector control mode | ||
| Speed stability | OLVC, 0.2%; CLVC: 0.1% | ||
| Torque response | ≤5ms, in Vector control mode | ||
| Acceleration/deceleration time | 0.0s~3200.0s; 0.0min~3200.0min | ||
| Torque boost | 0.0%~30.0% | ||
| Overload capacity | G model: 150% 1min/5min; 180%10s/5min; P model: 110% 1min/5min; 150% 10s/5min | ||
| V/F curve | Straight-line type, multi-point type, V/F Half separation mode, V/F complete separation mode | ||
| Input frequency resolution | Digital setting: 0.01Hz, Analog setting: 0.01Hz | ||
| Acceleration/deceleration curve | Straight line and S-curve | ||
| Main functions | Simple PLC, Multi-speed control | 16 speed segments supported through control terminals | |
| Automatic voltage regulation (AVR) | Automatically keeps the output voltage constant when grid voltage varies within a certain range | ||
| Fixed length control | Fixed length control | ||
| Built-in PID | Easily forms a closed-loop control system | ||
| Multi-motor switching | Switchover between two groups of motor parameters to control the two motors | ||
| Virtual I/O | Eight groups of virtual DI/DOenabling simple logic control | ||
| Overvoltage/Overcurrent stall control | Automatic current and voltage limitation during operation preventing the inverter from tripping due to frequent overcurrent or overvoltage | ||
| Restart after power failure | After power failure and restoration, the inverter waits for a set time before automatically running | ||
| Quick current limiting | Avoids frequent overcurrent faults in the inverter | ||
| Frequency setting method | keypad; terminal UP/DOWN; multi-reference; pulse reference; communication | ||
| Power input/ output | Analog input terminals | AI1; AI2: 0V~10V/ 0 (4)mA~20mA | |
| Digital input terminals | DI1-DI5, 5 programmable digital input terminals with
opto-isolation, compatible with both | ||
| Digital output terminals | Open-collector output; output voltage range: 0V~24V; current load
capacity: 50mA. | ||
| Analog output terminals | 1-channel 0V ~ 10V/0(4)mA ~ 20mA | ||
| Relay output | 1-channel Form C contact, NO+NC | ||
| Communication | Communication protocols | Modbus RTU (standard configuration); Profibus-DP; Profinet IO; CANopen; Modbus TCP/IP; Ethercat; EtherNet/IP (optional configuration) | |
| Ambient | Altitude | ≤1000m: no need for derating | |
| Ambient temperature | -25℃~+40℃ (Running with derating allowed between 40~55) | ||
| Humidity | 15% ~ 95%, No condensation | ||
| Vibration | 3M3, IEC60721-3-3 | ||
| Storage temperature | −40°C~+70°C | ||
| Installation place | Indoor, without direct sunlight, free from flammable, corrosive
gases, liquids, and conductive | ||
| Optional accessories | Encoder card, communication expansion card, IO expansion card | ||
| Protections | Protection against short circuit , overcurrent, overload,
overvoltage, undervoltage, phase loss, | ||
| Installation method | Installed in a cabinet | ||
| Protection rating | IP20 | ||
| Cooling method | Air cooling | ||
| HV350 Product Selection Rated voltage: three-phase 380Vac (suitable for operating voltage range of 323V~528V) | |||||
| Model | Heavy Load | Light Load | Frame Type | ||
| Rated Power (kW) | Rated Output Current | Rated Power | Rated Output Current | ||
| HV350-4T0.75G/1.5PB | 0.75 | 2.5 | 1.5 | 4.2 | FA | 
| HV350-4T1.5G/2.2PB | 1.5 | 4.2 | 2.2 | 5.8 | |
| HV350-4T2.2GB | 2.2 | 5.8 | - | - | |
| HV350-4T4G/5.5PB | 4 | 9.5 | 5.5 | 13 | FB | 
| HV350-4T5.5GB | 5.5 | 13 | - | - | |
| HV350-4T7.5G/11PB | 7.5 | 17 | 11 | 25 | FC | 
| HV350-4T11GB | 11 | 25 | - | - | |
| HV350-4T15G/18PB | 15 | 32 | 18.5 | 38 | FD | 
| HV350-4T18G/22PB | 18.5 | 38 | 22 | 46 | |
| HV350-4T22GB | 22 | 46 | - | - | |
| HV350-4T30G/37P(B) | 30 | 60 | 37 | 75 | FE | 
| HV350-4T37G/45P(B) | 37 | 75 | 45 | 91 | |
| HV350-4T45G/55P(B) | 45 | 91 | 55 | 125 | |
| HV350-4T55G/75P(B) | 55 | 125 | 75 | 150 | FF | 
| HV350-4T75G/90P(B) | 75 | 150 | 90 | 180 | |
| HV350-4T90G/110P(B) | 90 | 180 | 110 | 210 | FG | 
| HV350-4T110G/132P(B) | 110 | 210 | 132 | 250 | |

|   | 
 
                                 
                                 
                                 
                                